SA-LCMS-01ACTIVE SERVICE

LC-MS
ANALYSIS

Liquid Chromatography-Mass Spectrometry for high-sensitivity detection and quantification. The gold standard for peptide analysis, protein characterization, and complex molecule identification. Handles non-volatile, thermally labile, and high molecular weight compounds.

01APPLICATIONS
  • 01Peptide sequence confirmation
  • 02Protein quantification
  • 03Metabolite identification
  • 04Pharmacokinetic studies
  • 05Biomarker analysis
02METHOD OVERVIEW

LC-MS at Standard Analytica is optimized for the analysis of peptides, proteins, and complex biomolecules. Our platform supports both high-resolution accurate mass (HRAM) and triple-quadrupole configurations for maximum analytical flexibility.

The technique excels at characterizing non-volatile and thermally labile compounds that cannot be analyzed by GC-MS. Electrospray ionization (ESI) enables gentle ionization of large biomolecules while preserving structural information.

Our LC-MS workflows include full method development, validation, and transfer capabilities. All results are traceable to certified reference standards and performed under GLP-compliant conditions.

03TECHNICAL SPECIFICATIONS
PARAMETER
SPECIFICATION
Detection Range
0.1 ppb - 100%
Mass Range
50-3,000 m/z
Sample Types
Peptides, proteins, solutions
Min Sample Size
5 mg / 0.5 mL
Turnaround
48-72 hours standard
Report Format
PDF with spectra & chromatograms
SPECIFICATIONS SUBJECT TO SAMPLE TYPE AND COMPLEXITY // REV 2025.01
04TESTING PROCESS
01

SAMPLE INTAKE

Your sample is received, logged into our LIMS system, and assigned a unique tracking identifier. Temperature-sensitive samples are stored under controlled conditions immediately upon receipt.

02

PREPARATION

Samples undergo method-specific preparation including dissolution, enzymatic digestion, solid-phase extraction, or dilution as required by the analytical protocol.

03

ANALYSIS

Prepared samples are separated via liquid chromatography and detected using mass spectrometry. ESI and APCI ionization modes are available for comprehensive compound coverage.

04

REPORTING

Results including mass spectra, chromatograms, and quantitative data are compiled into a detailed report. Molecular weight confirmation and sequence coverage data are included where applicable.

SUBMIT A SAMPLE

Ready to submit a sample for LC-MS analysis? Contact our team to discuss your requirements, receive sample preparation guidelines, and initiate testing.

$150 / SAMPLE — TYPICAL TURNAROUND: 48-72 HOURS